Combined Efficiency in Patient QA

Log files powered by best-in-class Monte Carlo

  • Powerful combination of best-in-class SciMoCa™ Monte-Carlo dose calculation and log files
  • Task based automation for optimized workflow efficiency

Fast analysis of all sources of possible errors for increased patient safety

Proven efficiency, accuracy, and safety in Radiation Therapy

myQA iON is a unique Patient QA software environment featuring an automated workflow and best-in-class algorithm to maximize your efficiency and accuracy. Validate your most demanding treatment techniques while ensuring patient safety without compromise.

myQA iON offers you:

    • Fully automated 3D plan verification workflow
    • Easy identification of any sources of errors using the SciMoCa Monte Carlo algorithm and log files
    • Use of daily logs to explore the relevance of dose deviations from the treatment planning software or delivery system
    • Delivery of even the most complicated treatments with confidence

       

Combined Monte Carlo and log file Patient QA

myQA iON combines machine log files with a Monte Carlo algorithm from the beginning to the end of your patient treatments.

    • Achieve an accuracy of <1% with the SciMoCa Monte Carlo algorithm
    • Perform your pre-treatment QA with the SciMoCa Monte Carlo algorithm
    • Validate delivered dose during treatment with the SciMoCa Monte Carlo algorithm combined with log files
    • Prepare for an adaptive future with tools such as plan complexity analysis

       

Efficient task-based workflow

myQA iON has an optimized, automated workflow to save time and speed up your QA process.

    • Speed up your QA process with automated dose calculations, in the background
    • Assign tasks to specific users with the optimized patient or task lists view
    • Identify any potential errors or dose deviations using advanced, yet easy to use, tools

       

Safe delivery of patient treatment

To ensure accurate and unbiased QA results, a system is required that is unbiased and independent from the treatment planning system vendor.

    • Utilize all DICOM information from your based treatment planning systems
    • Analyze your results using advanced 3D tools such as DVH’s and clinical goals
    • Identify the source of any potential dose deviations or errors
    • Understand the clinical relevance and source of potential deviation and errors

       

Supported system

Treatment techniquesTreatment machinesTreatment Planning System
Photon and electron treatment techniques supportedElekta – all C-arm machines
Varian – all C-arm machines
Varian – Halcyon® and Ethos™

CyberKnife®, TomoTherapy®, Radixact®, Zap-X® and MR-linac devices coming soon

All TPS capable of DICOM-RT Export

Additional information:

  • 3D– with and without wedged fields
  • IMRT, IMAT, VMAT
  • SBRT, SRS, SRS cones

Additional information:

  • All photon and electron energies supported
  • All MLC devices supported
  • Both custom and standard beam models supported
  • Log files supported: .ivx, trajectory logs, DynaLog™
 

Recommended Server specifications

Operating SystemWindows Server 2016 or 2019 OS
CPU24-core
RAM64 GB
Free hard disk space2 6TB HDD drives
Web browserChrome™, Firefox™

 

Product Category